Carbonics Troubleshooting Guide
(Staff Edition)


Identify Customer's Problem!
  

CO2: leak, flat, no gas

  1. Is the tank empty?
  2. Did they have a washer?
  3. Check for current leak with handwheel and gauge
  4. If they don't have a leak, but lost a tank of gas, they could have had a missing BIB, or someone could have left a keg-coupler "open" at some point. We can only fix leaks that are happening at the time.
  5. If they have a leak, transfer to Service Manager
  6. If Sodas are flat, but syrup is coming out, then it's a brixing problem, or they if they just changed tanks they need to run the soda for a solid 60 seconds.
Going through too much gas!
  1. 1. Did they have a washer?
  2. Is there a leak?
  3. Did they run out of BIB for a while, but now they have a box hooked up?
  4. If they want a technician to come check it out, we charge a Service Charge, plus 1 hour labor: transfer to Service Manager.
Sodas are too Foamy
  1. Are they out of ice? That will make CO2 break out
  2. Dirty lines cause foam, are the lines clean, or do they need a Service Call for that?
  3. The primary regulator on a Soda system should be 100-105 PSI, if more then they are getting over-carbonated.
  4. They might just need a Brix: Transfer call to Service Manager
No Syrup out of my Soda dispenser/gun
  1. If no lines are working they are probably out of CO2
  2. If one line isn't working the QCD/BIB connection might not be good
  3. If one line isn't working, that pump might have failed: Transfer call to Service Manager
Nothing works soda dispenser
  1. The machine may have been turned off with a key
  2. machine may be unplugged
  3. Otherwise they should at least get water out of the valves. If not maybe electrical circuit has tripped
Sodas Are flat dispenser/gun
  1. Are they out of CO2 (empty tank)?
  2. Was the tank recently changed? If so, they will need to run soda for a solid 60 seconds
  3. The primary regulator for Soda system should be 100-105 PSI
  4. Do they have ice in the dispenser (or on the cold plate)? Warm sodas will be flat
  5. If they need a technician transfer call to Service Manager
Soda or Beer pump is making a constant sound
  1. If sound is a repetitive "puff" they are out of BIB syrup. They can put the connector is a bucket of water temporarily.
  2. If sound is continuous "hissss" their pump is probably blown, and they need a technician. If they are willing you can talk them through disconnecting the air-supply for that pump, otherwise, transfer call to Service Manager.
Beer is too Foamy!

Temperature / Pressure / Sanitation

  1. All lines = too warm (glycol chiller or cooler problem)
  2. If only one or a few lines they likely need a technician: Transfer call to Service Manager
Sodas Taste Funny
  1. If they recently changed the CO2 tank they may need to run soda for a solid 60 seconds
  2. System may need Brixing: transfer call to Service Manager

                                           